- identify water softener as Morton M34. Morton Water and Well Drilling - Morehead City NC | Call us Today! Many water softener models use a check valve at the top or at the bottom of a brine pick-up tube in the brine tank. We haven’t had any soft water since we installed it (rusty sinks/tubs) and water testing strips show high hardness. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. The water level (or briny water or brine level) in a water softener brine tank may be abnormally high, or it may simply fail to drop when the water softener goes through a regeneration cycle. In some phases the softener is drawing some house water and rinsing the tank into the building drain. I have a Morton softener that was just installed, and a culligan arsenic filter. Quoting an Amazon description: The NSFC Products List has an excellent list of design manuals/modules National Small Flows Clearinghouse (NSFC) now (2019/12/13) hosted at http://www.nesc.wvu.edu/ Tel: 304-293-4191 e-mail info@mail.nesc.wvu.edu. All seems good. I noticed the level of water in the brine tank is about 3/4 full. is to be based upon referee tests procedures described in section In the article below we will explain how to find, remove, clean, fix, or replace each of the water softener parts involved. So during a step that draws brine from the brine tank, salty water is drawn by the softener's control head through a tube connected to that control - that's the hose that you mentioned.Most softeners are limited in the flow rate through the softener as well as the lift-capacity of the softener to lift up wastewater to send it to the softener drain system. Your Home for Water Filters, Water Softeners, and Water … I noticed a salty looking floor like our salt tank over flowed. If your brine drain flow is much longer, much stronger, or very weak, check the diagnostic table we give below, and also see BRINE TANK WATER TOO LOW. Is it because our float inside it might have stuck? ©2016. Continue reading at BRINE TANK DIAGNOSIS & REPAIR or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. I’ve tested to see if it’s the brine well hose that is not pulling the brine through, and when I kink it myself, I continue to hear water being drained to my septic system. I have never seen the water so high and do recall being advised the water level should not be higher than 1/4 of the tank. Call us for your FREE water analysis today. I'm going to give this some thought.And just to avoid embarrassing ourselves, we are absolutely sure that the softener is not stuck in bypass mode, right? Notice a strange odor recently? We can help! We've tried to include synonyms for various water softener controls and parts but the best source of part names and locations is the manual for your specific water softener brand and model. Use of this product 3 times a year after purchasing a Morton softener to extend your softener from one year up … Full directions available on the back of the cleanser bottle. How can I get information on this system? The BRINE REFILL FLOAT CONTROL VALVE device is found in the vertical tube in your brine tank. Watch out: for completeness this checklist includes parts that may not be present on your water softener, or that may be addressed by a different name. Order individual softener Parts directly from Culligan as well as from plumbing suppliers or from a local Culligan Service Company. It is a model 740 - M.C., Canada. I just noticed today that there was still some water in my salt tank after the cycle Test un-softened water for hardness and iron then program the softener accordingly. Custom Website Design and Internet Marketing by Custom Websites ETC, specializing in water treatment and well drilling, Get a Free Consultation. This book is in the upper price range, but is worth the cost for serious septic installers and designers. 6. height or elevation of the water softener control head to the highest point on the drain lineDepending on your building's water pressure and the heights involved, your softener installation's drain may be exceeding the unit's ability to lift or push wastewater.Here is what the company says:If the water softener does not draw brine, our complete list of causes and cures is found, at WATER SOFTENER BRINE TANK WATER TOO HIGH. First check the water softener settings WATER SOFTENER ADJUSTMENT & CONTROLS . A stuck or damaged valve in some Autotrol heads, for example, can cause water to accumulate in the brine tank during the very time that it should be emptying out during softener regeneration. "The objective of this chapter is to provide a standard of quality, capacity, The height of the drain hose meets the suggestions of 8 feet or less and is less than 30 feet from the unit. We discuss how the brine refill control valve works and how it may be adjusted. A hose goes from the brine well to the top of softener where the control head is. Tel: +1 630-961-5043 Our next step is to check the eductor valve in the water softener, typically located in the water softener's control head. Start at BRINE TANK WATER TOO HIGH for complete diagnosis and repair. see WATER SOFTENER CLEANING & SANITIZING. Often you can also obtain the manual directly from your water softener's manufacturer. Remove the eductor cap - outermost component of the assembly in the red circle in our illustration. Is this something I need to worry about? Morton Drilling. We are a family owned company providing residential, commercial water wells and water treatment systems. Q. Find out what causes too much water in the water conditioner brine tank or salt tank & how do to fix it. Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. If the brine-water from the salt tank or brine tank is present but does not flow out of the brine tank, through the water softener resin and onwards to a softer drain disposal site, then the softener cannot regenerate and it will no longer be treating hard water - water will remain "hard" or high in calcium and magnesium. Builder's Greywater Guide, Art Ludwig; Buy New: $10.17. During the water softener regeneration cycle there are a number of steps that basically amount to flushing out the resin in the resin tank (that's where the softening actually takes place and will be the tank below the control head for the system), then sending salty water out of the brine tank (brine tank draw) through the resin tank to re-charge the resin beads with salt, and finally sending some water back into the brine tank so that the new water can dissolve salt to be ready for the next cycle. Apologies for the delay. Morton water softener models are factory assem- ® salt storage tank to level the softener. This valve closes when the brine level in the tank drops - at the end of a regen cycle - to prevent drawing air into the water softener itself. )While it contains some material more technical than needed by homeowners, Burks/Minnis book on onsite wastewater treatment systems a very useful reference Here we list the common causes of these two conditions, followed by a diagnostic table, followed by step by step suggestions of parts to check on the water softener and its brine tank. To identify the main components of a water softener click to enlarge the page top image. 3. 252-222-0513. InspectAPedia tolerates no conflicts of interest. Morton m34 is the unit. .The volume of water that is pumped into the brine tank and then out back through the water softener is set by the salt "dose" setting on the water softener control. When a water softener won't draw brine out of the brine tank (brine tank eduction failure) to use in a regeneration cycle the water level in the brine tank may stay the same or even increase at each backwash or regen cycle. Fax: 1 800-671-8846, Customer Service: 1 800-228-9326, Email: customers@ecodyneind.com, Website: http://www.ecodyneind.com/.